### Controlling LEDs (For Production Tests)
### Controlling LEDs for Production Tests
As part of production tests you wish to verify that LEDs work as
expected. Infix uses standard [Linux support for LED
As part of production testing, LED verification is often expected to
be performed. Infix uses standard [Linux support for LED
management][6], where LEDs appear in the file system under
/sys/class/leds and can be controlled using *echo* command. `sudo`
privileges are required.
@@ -344,39 +344,35 @@ daemon to avoid conflicting LED control.
```
~$ ssh admin@example.local 'initctl stop iitod'
~$
```
Then run your test, e.g., visually controll that a red LED labeled
Then run the test, e.g., visually control that a red LED labeled
'LAN' is working.
```
~$ ssh admin@example.local 'echo none | sudo tee /sys/class/leds/red\:lan/trigger'
~$ ssh admin@example.local 'echo 1 | sudo tee /sys/class/leds/red\:lan/brightness'
~$
~$ ssh admin@example.local 'echo 1 | sudo tee /sys/class/leds/red\:lan/brightness'
```
To turn off the same LED, run the following commands.
```
~$ ssh admin@example.local 'echo none | sudo tee /sys/class/leds/red\:lan/trigger'
~$ ssh admin@example.local 'echo 0 | sudo tee /sys/class/leds/red\:lan/brightness'
~$
~$ ssh admin@example.local 'echo 0 | sudo tee /sys/class/leds/red\:lan/brightness'
```
When done with LED testing, enable Infix *iitod* daemon again.
```
~$ ssh admin@example.local 'initctl start iitod'
~$
```
### Reading Power Feed Status (For Production Tests)
### Reading Power Feed Status for Production Tests
As part of production tests you wish to verify that Power Feed sensors work as
expected. Infix uses standard [Linux support for Power
management][7], where power sources appear in the file system under
/sys/class/power_supply. The following example reads status of two
power supplies named *pwr1* and *pwr2*.
As part of production tests, verification of Power Feed sensors is
often expected to be performed. Infix uses standard [Linux support for
Power management][7], where power sources appear in the file system
under /sys/class/power_supply. The following example reads status of
two power supplies named *pwr1* and *pwr2*.
```
~$ ssh admin@example 'cat /sys/class/power_supply/pwr1/online'
@@ -388,9 +384,6 @@ power supplies named *pwr1* and *pwr2*.
Here, only *pwr1* happened to have power.
## Examples using SSH and sysrepocfg
@@ -405,10 +398,10 @@ See [sysrepocfg][4] for information. Examples below will utilize
- `sysrepocfg -I FILE -fjson -d DATABASE` to import/write a JSON
formatted configuration file to the specificed database.
formatted configuration file to the specified database.
- `sysrepocfg -E FILE -fjson -d DATABASE` to edit/merge JSON formatted
configuration in FILE with the specificed database.
- `sysrepocfg -R FILE -fjson` to execute remote procdure call (RPC) defined in
configuration in FILE with the specified database.
- `sysrepocfg -R FILE -fjson` to execute remote procedure call (RPC) defined in
FILE (JSON formatted).
- `sysrepocfg -X -fjson -d DATABASE -x xpath` to read configuration or
status from specified database.
@@ -419,7 +412,7 @@ configuration. Exporting (-X) could operate on configuration (e.g.,
`-d running`) or status (`-d operational`).
Some commands require a file as input. In examples below we assume
it been transfered to Infix in advance, e.g. using `scp` as shown below.
it been transferred to Infix in advance, e.g. using `scp` as shown below.
```
~$ cat file.json
@@ -447,7 +440,7 @@ it been transfered to Infix in advance, e.g. using `scp` as shown below.
```
See [Factory Reset](#factory-reset) for another (simpler) alternative.
If you only wish to copy factory config to running config the
If it is only wished to copy factory config to running config the
following RPC is available
```
@@ -793,14 +786,15 @@ models for details.
## Miscellaneous
### <a id="port-test-intro"></a> Port Test Configuration Example (For Production Tests)
### <a id="port-test-intro"></a> Port Configuration Example for Production Tests
In production you wish to test that all ports work. A common way is to
connect a test PC to two ports and send a *ping* traversing all ports.
This can be achieved by using VLANs on the switch as described in this
section. The resulting configuration file can be applied to the
running configuration of the produced unit, e.g, use config file
restore as described [above](#restore).
As part of production tests, verification Ethernet ports are expected
to be performed. A common way is to connect a test PC to two ports and
send a *ping* traversing all ports. This can be achieved by using
VLANs on the switch as described in this section. The resulting
configuration file can be applied to the running configuration of the
produced unit, e.g, use config file restore as described
[above](#restore).
In this example we assume a 10 port switch, with ports e1-e10.
@@ -817,13 +811,10 @@ The following VLAN configuration and cable connections will be used:
The test PC is connected to e1 and e10 via different interfaces
(alternatively, two different PCs are used).
> Configuration here is done via console. If you intend to do it via
> Ethernet and SSH, be careful so that you do not lose
> connectivity. Either stay in "configuration context" until done, or
> make sure there is always an IP (IPv6 or IPv4) address available on
> the switch which you can connect to. Section [Add IP on
> Switch](#ip-on-switch) gives an example.
> Configuration here is done via console. When configuring remotely
> over SSH, remember to keep one IP address (the one used for the SSH
> connection)! I.e., set a static IP address first, then perform the
> VLAN configuration step."
#### Configuration at Start
@@ -851,8 +842,7 @@ admin@example:/>
#### Creating Bridge and Adding Ports
Example below use Infix documentation on [creating
bridges][8].
The example below uses Infix documentation on [creating bridges][8].
``` shell
admin@example:/> configure
@@ -871,12 +861,13 @@ admin@example:/config/> set interface e10 bridge-port bridge br0
admin@example:/config/>
```
If you wish, you can check interface status. But beware that you may
lose connectivity when leaving *configuration context* if configuring
via SSH. Then it is better to first assign an IPv6 address to br0
(`set interface br0 ipv6 enabled`) before leaving. Or skip 'leave' and
stay in configuration context until done with all sections, including
the one on [Add IP on Switch](#ip-on-switch).
The interface status can be viewed using "show interface" after
leaving configuration context. If configuration via SSH, first assign
an IP address to br0 before *leaving* configuration context, e.g.,
`set interface br0 ipv6 enabled` to get auto-configured IPv6
address. Or skip 'leave' and stay in configuration context until done
with all sections, including the one on [Add IP on
Switch](#ip-on-switch).
``` shell
admin@example:/config/> leave
@@ -903,11 +894,10 @@ admin@example:/>
#### Assign VLANs to Ports
Then we configure VLANs according to plan
[above](#port-test-intro). We configure default VID for ingress
(PVID), which is done per port, and egress mode (untagged), which is
done at the bridge level. See Infix [documentation for VLAN
bridges][9] for more information.
Then configure VLANs as outlined [above](#port-test-intro):
default VID for ingress (PVID), which is done per port, and egress
mode (untagged), which is done at the bridge level. See Infix
[documentation for VLAN bridges][9] for more information.
``` shell
@@ -1096,7 +1086,7 @@ vlan10 ethernet UP 00:53:00:06:11:01
admin@example:/>
```
If you now ping "IPv6 all hosts" from the PC, you should get two
When pinging "IPv6 all hosts" from the PC, there should be two
responses for every ping, one from the switch and one from the PC
attached to e10.
@@ -1118,7 +1108,7 @@ rtt min/avg/max/mdev = 0.452/0.631/0.968/0.211 ms
~ $
```
Now you can access the switch from the PC via SSH (or NETCONF).
It should now be possible to access the switch from the PC via SSH (or NETCONF).
``` shell
~ $ ssh admin@fe80::0053:00ff:fe06:1101%eth1
@@ -1135,7 +1125,7 @@ admin@example:~$ exit
```
See previous sections on [backup](#backup) and [restore](#restore) of
your created configuration.
the created configuration.