mirror of
https://github.com/kernelkit/infix.git
synced 2026-07-22 01:13:00 +02:00
Updating text after feedback.
I found similar error in other parts of the doc, as well as some typos, and fixed them there too. [skip ci]
This commit is contained in:
+44
-54
@@ -331,10 +331,10 @@ admin@infix.local%eth0's password: *****
|
||||
~$
|
||||
```
|
||||
|
||||
### Controlling LEDs (For Production Tests)
|
||||
### Controlling LEDs for Production Tests
|
||||
|
||||
As part of production tests you wish to verify that LEDs work as
|
||||
expected. Infix uses standard [Linux support for LED
|
||||
As part of production testing, LED verification is often expected to
|
||||
be performed. Infix uses standard [Linux support for LED
|
||||
management][6], where LEDs appear in the file system under
|
||||
/sys/class/leds and can be controlled using *echo* command. `sudo`
|
||||
privileges are required.
|
||||
@@ -344,39 +344,35 @@ daemon to avoid conflicting LED control.
|
||||
|
||||
```
|
||||
~$ ssh admin@example.local 'initctl stop iitod'
|
||||
~$
|
||||
```
|
||||
|
||||
Then run your test, e.g., visually controll that a red LED labeled
|
||||
Then run the test, e.g., visually control that a red LED labeled
|
||||
'LAN' is working.
|
||||
|
||||
```
|
||||
~$ ssh admin@example.local 'echo none | sudo tee /sys/class/leds/red\:lan/trigger'
|
||||
~$ ssh admin@example.local 'echo 1 | sudo tee /sys/class/leds/red\:lan/brightness'
|
||||
~$
|
||||
~$ ssh admin@example.local 'echo 1 | sudo tee /sys/class/leds/red\:lan/brightness'
|
||||
```
|
||||
|
||||
To turn off the same LED, run the following commands.
|
||||
|
||||
```
|
||||
~$ ssh admin@example.local 'echo none | sudo tee /sys/class/leds/red\:lan/trigger'
|
||||
~$ ssh admin@example.local 'echo 0 | sudo tee /sys/class/leds/red\:lan/brightness'
|
||||
~$
|
||||
~$ ssh admin@example.local 'echo 0 | sudo tee /sys/class/leds/red\:lan/brightness'
|
||||
```
|
||||
When done with LED testing, enable Infix *iitod* daemon again.
|
||||
|
||||
```
|
||||
~$ ssh admin@example.local 'initctl start iitod'
|
||||
~$
|
||||
```
|
||||
|
||||
### Reading Power Feed Status (For Production Tests)
|
||||
### Reading Power Feed Status for Production Tests
|
||||
|
||||
As part of production tests you wish to verify that Power Feed sensors work as
|
||||
expected. Infix uses standard [Linux support for Power
|
||||
management][7], where power sources appear in the file system under
|
||||
/sys/class/power_supply. The following example reads status of two
|
||||
power supplies named *pwr1* and *pwr2*.
|
||||
As part of production tests, verification of Power Feed sensors is
|
||||
often expected to be performed. Infix uses standard [Linux support for
|
||||
Power management][7], where power sources appear in the file system
|
||||
under /sys/class/power_supply. The following example reads status of
|
||||
two power supplies named *pwr1* and *pwr2*.
|
||||
|
||||
```
|
||||
~$ ssh admin@example 'cat /sys/class/power_supply/pwr1/online'
|
||||
@@ -388,9 +384,6 @@ power supplies named *pwr1* and *pwr2*.
|
||||
Here, only *pwr1* happened to have power.
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
## Examples using SSH and sysrepocfg
|
||||
|
||||
|
||||
@@ -405,10 +398,10 @@ See [sysrepocfg][4] for information. Examples below will utilize
|
||||
|
||||
|
||||
- `sysrepocfg -I FILE -fjson -d DATABASE` to import/write a JSON
|
||||
formatted configuration file to the specificed database.
|
||||
formatted configuration file to the specified database.
|
||||
- `sysrepocfg -E FILE -fjson -d DATABASE` to edit/merge JSON formatted
|
||||
configuration in FILE with the specificed database.
|
||||
- `sysrepocfg -R FILE -fjson` to execute remote procdure call (RPC) defined in
|
||||
configuration in FILE with the specified database.
|
||||
- `sysrepocfg -R FILE -fjson` to execute remote procedure call (RPC) defined in
|
||||
FILE (JSON formatted).
|
||||
- `sysrepocfg -X -fjson -d DATABASE -x xpath` to read configuration or
|
||||
status from specified database.
|
||||
@@ -419,7 +412,7 @@ configuration. Exporting (-X) could operate on configuration (e.g.,
|
||||
`-d running`) or status (`-d operational`).
|
||||
|
||||
Some commands require a file as input. In examples below we assume
|
||||
it been transfered to Infix in advance, e.g. using `scp` as shown below.
|
||||
it been transferred to Infix in advance, e.g. using `scp` as shown below.
|
||||
|
||||
```
|
||||
~$ cat file.json
|
||||
@@ -447,7 +440,7 @@ it been transfered to Infix in advance, e.g. using `scp` as shown below.
|
||||
```
|
||||
See [Factory Reset](#factory-reset) for another (simpler) alternative.
|
||||
|
||||
If you only wish to copy factory config to running config the
|
||||
If it is only wished to copy factory config to running config the
|
||||
following RPC is available
|
||||
|
||||
```
|
||||
@@ -793,14 +786,15 @@ models for details.
|
||||
|
||||
## Miscellaneous
|
||||
|
||||
### <a id="port-test-intro"></a> Port Test Configuration Example (For Production Tests)
|
||||
### <a id="port-test-intro"></a> Port Configuration Example for Production Tests
|
||||
|
||||
In production you wish to test that all ports work. A common way is to
|
||||
connect a test PC to two ports and send a *ping* traversing all ports.
|
||||
This can be achieved by using VLANs on the switch as described in this
|
||||
section. The resulting configuration file can be applied to the
|
||||
running configuration of the produced unit, e.g, use config file
|
||||
restore as described [above](#restore).
|
||||
As part of production tests, verification Ethernet ports are expected
|
||||
to be performed. A common way is to connect a test PC to two ports and
|
||||
send a *ping* traversing all ports. This can be achieved by using
|
||||
VLANs on the switch as described in this section. The resulting
|
||||
configuration file can be applied to the running configuration of the
|
||||
produced unit, e.g, use config file restore as described
|
||||
[above](#restore).
|
||||
|
||||
In this example we assume a 10 port switch, with ports e1-e10.
|
||||
|
||||
@@ -817,13 +811,10 @@ The following VLAN configuration and cable connections will be used:
|
||||
The test PC is connected to e1 and e10 via different interfaces
|
||||
(alternatively, two different PCs are used).
|
||||
|
||||
> Configuration here is done via console. If you intend to do it via
|
||||
> Ethernet and SSH, be careful so that you do not lose
|
||||
> connectivity. Either stay in "configuration context" until done, or
|
||||
> make sure there is always an IP (IPv6 or IPv4) address available on
|
||||
> the switch which you can connect to. Section [Add IP on
|
||||
> Switch](#ip-on-switch) gives an example.
|
||||
|
||||
> Configuration here is done via console. When configuring remotely
|
||||
> over SSH, remember to keep one IP address (the one used for the SSH
|
||||
> connection)! I.e., set a static IP address first, then perform the
|
||||
> VLAN configuration step."
|
||||
|
||||
#### Configuration at Start
|
||||
|
||||
@@ -851,8 +842,7 @@ admin@example:/>
|
||||
|
||||
#### Creating Bridge and Adding Ports
|
||||
|
||||
Example below use Infix documentation on [creating
|
||||
bridges][8].
|
||||
The example below uses Infix documentation on [creating bridges][8].
|
||||
|
||||
``` shell
|
||||
admin@example:/> configure
|
||||
@@ -871,12 +861,13 @@ admin@example:/config/> set interface e10 bridge-port bridge br0
|
||||
admin@example:/config/>
|
||||
```
|
||||
|
||||
If you wish, you can check interface status. But beware that you may
|
||||
lose connectivity when leaving *configuration context* if configuring
|
||||
via SSH. Then it is better to first assign an IPv6 address to br0
|
||||
(`set interface br0 ipv6 enabled`) before leaving. Or skip 'leave' and
|
||||
stay in configuration context until done with all sections, including
|
||||
the one on [Add IP on Switch](#ip-on-switch).
|
||||
The interface status can be viewed using "show interface" after
|
||||
leaving configuration context. If configuration via SSH, first assign
|
||||
an IP address to br0 before *leaving* configuration context, e.g.,
|
||||
`set interface br0 ipv6 enabled` to get auto-configured IPv6
|
||||
address. Or skip 'leave' and stay in configuration context until done
|
||||
with all sections, including the one on [Add IP on
|
||||
Switch](#ip-on-switch).
|
||||
|
||||
``` shell
|
||||
admin@example:/config/> leave
|
||||
@@ -903,11 +894,10 @@ admin@example:/>
|
||||
|
||||
#### Assign VLANs to Ports
|
||||
|
||||
Then we configure VLANs according to plan
|
||||
[above](#port-test-intro). We configure default VID for ingress
|
||||
(PVID), which is done per port, and egress mode (untagged), which is
|
||||
done at the bridge level. See Infix [documentation for VLAN
|
||||
bridges][9] for more information.
|
||||
Then configure VLANs as outlined [above](#port-test-intro):
|
||||
default VID for ingress (PVID), which is done per port, and egress
|
||||
mode (untagged), which is done at the bridge level. See Infix
|
||||
[documentation for VLAN bridges][9] for more information.
|
||||
|
||||
|
||||
``` shell
|
||||
@@ -1096,7 +1086,7 @@ vlan10 ethernet UP 00:53:00:06:11:01
|
||||
admin@example:/>
|
||||
```
|
||||
|
||||
If you now ping "IPv6 all hosts" from the PC, you should get two
|
||||
When pinging "IPv6 all hosts" from the PC, there should be two
|
||||
responses for every ping, one from the switch and one from the PC
|
||||
attached to e10.
|
||||
|
||||
@@ -1118,7 +1108,7 @@ rtt min/avg/max/mdev = 0.452/0.631/0.968/0.211 ms
|
||||
~ $
|
||||
```
|
||||
|
||||
Now you can access the switch from the PC via SSH (or NETCONF).
|
||||
It should now be possible to access the switch from the PC via SSH (or NETCONF).
|
||||
|
||||
``` shell
|
||||
~ $ ssh admin@fe80::0053:00ff:fe06:1101%eth1
|
||||
@@ -1135,7 +1125,7 @@ admin@example:~$ exit
|
||||
```
|
||||
|
||||
See previous sections on [backup](#backup) and [restore](#restore) of
|
||||
your created configuration.
|
||||
the created configuration.
|
||||
|
||||
|
||||
|
||||
|
||||
Reference in New Issue
Block a user