forked from peter/volvo2mqtt
Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
974ad0e454 | ||
|
|
7db02b5dc6 | ||
|
|
7c87c71ac8 | ||
|
|
3482a5f893 | ||
|
|
3f1f793c1b | ||
|
|
1039eab649 |
@@ -72,7 +72,7 @@ NOTE: Energy status currently available only for cars in the Europe / Middle Eas
|
||||
Just install this addon with the following command.
|
||||
Please note to fill in your settings inside the environment variables.
|
||||
|
||||
`docker run -d --pull=always -e CONF_updateInterval=300 -e CONF_babelLocale='de' -e CONF_mqtt='@json {"broker": "", "username": "", "password": "", "port": 1883}' -e CONF_volvoData='@json {"username": "", "password": "", "vin": "", "vccapikey": "", "backupvccapikey": "", "odometerMultiplier": 1, "averageSpeedDivider": 1, "averageFuelConsumptionMultiplier": 1}' -e TZ='Europe/Berlin' --name volvo2mqtt ghcr.io/dielee/volvo2mqtt:latest`
|
||||
`docker run -d --pull=always -e CONF_updateInterval=300 -e CONF_babelLocale='de' -e CONF_mqtt='@json {"broker": "", "username": "", "password": "", "port": 1883}' -e CONF_volvoData='@json {"username": "", "password": "", "vin": "", "vccapikey": ["key1", "key2"], "odometerMultiplier": 1, "averageSpeedDivider": 1, "averageFuelConsumptionMultiplier": 1}' -e TZ='Europe/Berlin' --name volvo2mqtt ghcr.io/dielee/volvo2mqtt:latest`
|
||||
|
||||
<b>HA Add-On:</b><br>
|
||||
|
||||
|
||||
@@ -1,3 +1,15 @@
|
||||
## v1.8.3
|
||||
### 🚀 Features:
|
||||
|
||||
- Add `device_class: battery` for battery state sensors from BEV and PHEV
|
||||
|
||||
## v1.8.2
|
||||
### 🚀 Features:
|
||||
|
||||
- Add `updateInterval` limit to prevent abuse (60 Seconds)
|
||||
- Add `vccapikey` limit to prevent abuse (3 Keys)
|
||||
- Optimize vcc api key change behaviour
|
||||
|
||||
## v1.8.1
|
||||
### 🐛 Bug Fixes:
|
||||
|
||||
|
||||
+2
-2
@@ -1,6 +1,6 @@
|
||||
name: "Volvo2Mqtt"
|
||||
description: "Volvo AAOS MQTT bridge"
|
||||
version: "1.8.1"
|
||||
version: "1.8.3"
|
||||
slug: "volvo2mqtt"
|
||||
init: false
|
||||
url: "https://github.com/Dielee/volvo2mqtt"
|
||||
@@ -29,7 +29,7 @@ options:
|
||||
averageSpeedDivider: 1
|
||||
averageFuelConsumptionMultiplier: 1
|
||||
schema:
|
||||
updateInterval: int(10,)
|
||||
updateInterval: int(60,)
|
||||
babelLocale: str
|
||||
TZ: str
|
||||
debug: bool
|
||||
|
||||
+3
-3
@@ -1,6 +1,6 @@
|
||||
from config import settings
|
||||
|
||||
VERSION = "v1.8.1"
|
||||
VERSION = "v1.8.3"
|
||||
|
||||
OAUTH_URL = "https://volvoid.eu.volvocars.com/as/token.oauth2"
|
||||
VEHICLES_URL = "https://api.volvocars.com/connected-vehicle/v1/vehicles"
|
||||
@@ -77,8 +77,8 @@ icon_states = {
|
||||
}
|
||||
|
||||
supported_entities = [
|
||||
{"name": "Battery Charge Level", "domain": "sensor", "id": "battery_charge_level", "unit": "%", "icon": "car-battery", "url": RECHARGE_STATE_URL, "state_class": "measurement"},
|
||||
{"name": "Battery Charge Level", "domain": "sensor", "id": "battery_charge_level", "unit": "%", "icon": "car-battery", "url": BATTERY_CHARGE_STATE_URL, "state_class": "measurement"},
|
||||
{"name": "Battery Charge Level", "domain": "sensor", "device_class": "battery", "id": "battery_charge_level", "unit": "%", "icon": "car-battery", "url": RECHARGE_STATE_URL, "state_class": "measurement"},
|
||||
{"name": "Battery Charge Level", "domain": "sensor", "device_class": "battery", "id": "battery_charge_level", "unit": "%", "icon": "car-battery", "url": BATTERY_CHARGE_STATE_URL, "state_class": "measurement"},
|
||||
{"name": "Electric Range", "domain": "sensor", "id": "electric_range", "unit": "km" if not units.get(settings["babelLocale"]) else units[settings["babelLocale"]]["electric_range"]["unit"], "icon": "map-marker-distance", "url": RECHARGE_STATE_URL, "state_class": "measurement"},
|
||||
{"name": "Estimated Charging Time", "domain": "sensor", "id": "estimated_charging_time", "unit": "minutes", "icon": "timer-sync-outline", "url": RECHARGE_STATE_URL, "state_class": "measurement"},
|
||||
{"name": "Charging System Status", "domain": "sensor", "id": "charging_system_status", "icon": "ev-station", "url": RECHARGE_STATE_URL},
|
||||
|
||||
+4
-3
@@ -2,14 +2,15 @@ import logging
|
||||
from volvo import authorize
|
||||
from mqtt import update_loop, connect
|
||||
from const import VERSION
|
||||
from util import set_tz, setup_logging, set_mqtt_settings
|
||||
from util import set_tz, setup_logging, set_mqtt_settings, validate_settings
|
||||
|
||||
|
||||
if __name__ == '__main__':
|
||||
set_tz()
|
||||
set_mqtt_settings()
|
||||
setup_logging()
|
||||
logging.info("Starting volvo2mqtt version " + VERSION)
|
||||
validate_settings()
|
||||
set_tz()
|
||||
set_mqtt_settings()
|
||||
connect()
|
||||
authorize()
|
||||
update_loop()
|
||||
|
||||
+12
@@ -136,3 +136,15 @@ def set_mqtt_settings():
|
||||
config.settings["mqtt"]["port"] = broker_port
|
||||
config.settings["mqtt"]["username"] = broker_user
|
||||
config.settings["mqtt"]["password"] = broker_pass
|
||||
|
||||
|
||||
def validate_settings():
|
||||
if not os.environ.get("DEV_MODE"):
|
||||
setting_keys = settings.volvoData["vccapikey"]
|
||||
if isinstance(setting_keys, list):
|
||||
if len(setting_keys) > 3:
|
||||
raise Exception("Settings invalid! Maximum allowed vccapikeys are three!")
|
||||
|
||||
update_interval = settings["updateInterval"]
|
||||
if update_interval < 60:
|
||||
raise Exception("Settings invalid! Minimum allowed update interval is 60 seconds!")
|
||||
|
||||
+26
-20
@@ -119,28 +119,32 @@ def get_vehicles():
|
||||
|
||||
|
||||
def get_vcc_api_keys(used_key=None):
|
||||
setting_keys = settings.volvoData["vccapikey"]
|
||||
if isinstance(setting_keys, str):
|
||||
set_key_state(setting_keys)
|
||||
elif isinstance(setting_keys, list):
|
||||
for key in setting_keys:
|
||||
set_key_state(key)
|
||||
working_keys = None
|
||||
|
||||
logging.debug(str(vcc_api_keys))
|
||||
working_keys = [key["key"] for key in vcc_api_keys if not key.get("extended") and key.get('key') != used_key]
|
||||
if len(working_keys) < 1:
|
||||
logging.warning("No working VCCAPIKEY found, waiting 10 minutes. Then trying again!")
|
||||
mqtt.send_offline()
|
||||
time.sleep(600)
|
||||
get_vcc_api_keys(used_key=None)
|
||||
return None
|
||||
while not working_keys:
|
||||
setting_keys = settings.volvoData["vccapikey"]
|
||||
if isinstance(setting_keys, str):
|
||||
set_key_state(setting_keys)
|
||||
elif isinstance(setting_keys, list):
|
||||
for key in setting_keys:
|
||||
set_key_state(key)
|
||||
|
||||
mqtt.send_heartbeat()
|
||||
session.headers.update({"vcc-api-key": working_keys[0]})
|
||||
logging.info("Using VCCAPIKEY: " + working_keys[0])
|
||||
for key_dict in vcc_api_keys:
|
||||
if key_dict["key"] == working_keys[0]:
|
||||
key_dict["in_use"] = True
|
||||
logging.debug(str(vcc_api_keys))
|
||||
working_keys = [key["key"] for key in vcc_api_keys if not key.get("extended") and key.get('key') != used_key]
|
||||
if len(working_keys) < 1:
|
||||
used_key = None
|
||||
logging.warning("No working VCCAPIKEY found, waiting 10 minutes. Then trying again!")
|
||||
mqtt.send_offline()
|
||||
time.sleep(600)
|
||||
else:
|
||||
mqtt.send_heartbeat()
|
||||
session.headers.update({"vcc-api-key": working_keys[0]})
|
||||
logging.info("Using VCCAPIKEY: " + working_keys[0])
|
||||
for key_dict in vcc_api_keys:
|
||||
if key_dict["key"] == working_keys[0]:
|
||||
key_dict["in_use"] = True
|
||||
|
||||
logging.debug(str(vcc_api_keys))
|
||||
|
||||
|
||||
def set_key_state(key):
|
||||
@@ -160,6 +164,8 @@ def set_key_state(key):
|
||||
def check_vcc_api_key(test_key, extended_until=None):
|
||||
if extended_until:
|
||||
if extended_until >= datetime.now():
|
||||
logging.warning("VCCAPIKEY " + test_key + " is extended and will be reusable at: "
|
||||
+ format_datetime(extended_until, format="medium", locale=settings["babelLocale"]))
|
||||
return True, extended_until
|
||||
|
||||
if datetime.now(util.TZ) >= token_expires_at:
|
||||
|
||||
Reference in New Issue
Block a user