This patch unlocks "routing interfaces" support in the ietf-routing yang
model. An array of interface with IP forwarding enabled.
Note, because of #515 we skip IPv6 forwarding for now. This will in the
near future be handled by a per-interface force_forwarding sysctl flag.
The 'show interface [ifname]' admin-exec command has been extended with
a Flags field for a quick overview of which interfaces have forwarding
currently enabled.
Fixes#647
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
This fixes the following log message on systems w/o firewall enabled
dumping operational data:
Dec 2 09:24:57 test-00-02-00 yanger[5352]: Failed to connect to firewalld D-Bus: org.freedesktop.DBus.Error.ServiceUnknown: The name org.fedoraproject.FirewallD1 was not provided by any .service files
[skip ci]
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Due to their nature we cannot read out the RPM of the pwm fans on the
BPi-R3. But we can at least show it's alive, or steering out a signal
to the fan.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
The EXPIRES column was misaligned due to multiple issues:
- Column header used width 10 while data rows used width 9
- Expiry values had leading space intended for the narrower width
- CLIENT ID column width (19) was too narrow for typical client IDs
like "01:00:a0:85:00:01:05" (20 chars), causing overflow
Fixed by using consistent width for EXPIRES, removing the leading
space from expiry values, and widening CLIENT ID column to 22.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
The isoformat() method already includes the timezone offset when the
datetime object has timezone info. Appending "+00:00" created an
invalid double-timezone suffix like "2025-11-30T13:13:49+00:00+00:00"
which failed YANG validation.
Error was:
admin@bpi-26-60-00:/> show dhcp-server
Error running sysrepocfg: Command '['sysrepocfg', '-f', 'json', '-X',
'-d', 'operational', '-x', '/infix-dhcp-server:dhcp-server']' returned
non-zero exit status 1.
No interface data retrieved.
With syslog showing:
statd[4291]: libyang[0]: Invalid union value
"2025-11-30T13:13:49+00:00+00:00" - no matching subtype found
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Collect more data from FRR to the OSPF and BFD operational datastore.
Refactor CLI commands to use the YANG datastore instead of vtysh.
Additionally, the BFD command(s) have been moved to the top level of
admin-exec, which is where vtysh has them.
Finally, preparing for future OSPFv3 support, all commands have been
given a new context under 'show ip ospf'. Deprecation warnings have
been added to the existing 'show ospf' commands.
Also, for consistency, all commands names in plural have been changed to
their singular form: routes -> route, interfaes -> interface, etc. This
is what vtysh, Cisco, and others do as well.
Fixes#1190
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Wrap wpa_cli operations in try-except blocks to ensure WiFi errors don't
cause sysrepocfg to fail. Interface queries now return data for working
interfaces even when WiFi has issues.
Fixes:
admin@rpi-79-41-1d:/> show interfaces
Error running sysrepocfg: Command '['sysrepocfg', '-f', 'json', '-X', '-d', 'operational', '-x', '/ietf-interfaces:interfaces']' returned non-zero exit status 1.
No interface data retrieved.
admin@rpi-79-41-1d:/>
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
The xPi's usually don't have a VPD so the chassis mac-address probed at
boot is usually null in /run/system.json. This commit adds a fallbkack
mechanism to populate this field so it can be used for unique hostnames
even on these boards.
Ths ietf-hardware.yang model does not have a notion of physical address,
so we augment one tht is generic enought to be used for other hardware
components than Ethernet, similar to what ietf-interfaces.yang use.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
For more advanced hardware with multiple sensor types per device
(e.g., SFP modules with temperature, voltage, current, and power
sensors), use the YANG parent/child relationship to group related
sensors together for better presentation.
Changes:
- Remove parent/parent-rel-pos deviations from infix-hardware.yang
- Create parent components (class: module) for multi-sensor devices
- Add parent references to child sensor components
- Add human-readable descriptions from hwmon labels
- Extend hwmon discovery to support voltage, current, and power
- Normalize sensor names: strip vendor prefixes (mt7915_phy0 -> phy0)
- Remove redundant TYPE column, clarify units (V -> VDC, add spaces)
- Simplify child sensor display by stripping parent prefix
- Fix "show system" to only show CPU temperature and fan speed
Example output from "show hardware":
NAME VALUE STATUS
===================================================
sfp1:
Rx Power 0.000 W ok
Tx Power 0.001 W ok
Vcc 3.35 VDC ok
Bias 0.006 A ok
Temperature 30.3 °C ok
sfp2:
Rx Power 0.000 W ok
Tx Power 0.001 W ok
Vcc 3.34 VDC ok
Bias 0.006 A ok
Temperature 32.0 °C ok
cpu 42.8 °C ok
phy0 47.0 °C ok
phy1 53.0 °C ok
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
This commit adds resource usage: memory, loadavg, and filesystem usage
by augmenting ietf-system:/system-state.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
- Remove class deviation to allow iana-hardware:sensor
- Populate sensor operational data from /sys/class/thermal
- Extend 'show hardware'
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
This patch adds operational data support for system services. The
data is in a generic format but is intended to be able to represent
finit information (initctl) nicely.
The reason for augmenting this to ietf-system and not to
infix-services is that we consider this generic system information
which is totally disconnected from what ever services infix might
provide.
In this first state we only support pid, name, description and state.
Making the data look something like:
"infix-system:services": {
"service": [
{
"pid": 1185,
"name": "udevd",
"status": "running",
"description": "Device event daemon (udev)"
}]
Signed-off-by: Richard Alpe <richard@bit42.se>
Add supoprt for infix-firewall.yang, modeled on the zone-based firewalld
The terminology is a mix of firewalld, classic netfilter and inspired by
Ubiquity. E.g., zone 'policy' -> 'action', and the zone matrix overview.
- Port forwarding allows forwarding a range of ports
- Operational data comes from firewalld active rules
- Firewall logging goes to /var/log/firewall.log
- Show implicit/built-in rules and zones (HOST) in firewall matrix,
includes "locked" policy for the default-drop behavior
- The zone services field in admin-exec 'show firewall' shows ANY when
the zone default action is set to 'accept'
- Zone 'forwarding' and 'masquerade' settings live in Infix in the
policys instead, meaning users need to explicitly add a policy
to allow both intra-zone and inter-zone forwarding
- Support for emergency lockdown (kill switch)
- Pre-defined services (xml+enums) are filtered and included as a
separate YANG model, extensions added for netconf and restconf
- Includes initial support for firewalld rich rules
firewalld policy rules, including rich rules, have an obnoxious priority
field which is extremely hard to get right, so in Infix we use the far
superior YANG construct 'ordered-by user;'. This ensure all rules are
generated in that order by setting the priority field, on read-back from
firewalld (operational) the priority field is used to sort the output
of rules in the CLI.
Fixes#448
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Fix a bug where systems with OSPF enabled on some, but not all,
interfaces would cause the OSPF iterator to fail when accessing
iface['area'], which was missing. This caused the ospf_status.py
tool to return {}, resulting in empty OSPF data in sysrepo.
Fixes#1169 Expected neighbors not shown in sysrepocfg
Signed-off-by: Richard Alpe <richard@bit42.se>
Prior to this commit yanger looked at the running system using
os.path..., this meant that the static reply / capture data wasn't
used properly. This resulted in strange behavior during unit testing
on GitHub runners where USB ports are missing.
Signed-off-by: Richard Alpe <richard@bit42.se>
Libyang is smart, it "fixes" the timezone for you, this was overriden by a
hack in netconf.py and restconf.py, but what you really want is to see
in operational what the current timezone is.
When running a DHCP test `resolvconf -l` looked like this:
admin@client:~$ resolvconf -l
search example.com # e5
admin@client:~$
This resulted in broken result when reading operational data from
system-state (which used resolvonf -l)
Counters should follow the format from ieee802-ethernet-interface
model, which use:
- in/out for Rx/Tx
- plural from
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
- dnsmasq:
- allow listening to all interfaces again to serve DHCP leases
- disable most of the default DHCP options, keep broadcast and
netmask because when dnsmasq can infer these they are better
than breaking networking for clients -- note, they can still
be overridden from global/subnet/host scope -- and for relay
setups they need to be supplied anyway
- confd:
- drop per-interface dnsmasq, although practical for many use-cases,
having a per-subnet focused server means improved integration with
future stand-alone dhcp relay setup
- implement suggested, simplified, yang model
Fixes#703
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
This patch introduces a new yang yang model for DHCP server and relay,
using dnsmasq to provide the functionality on a per-interface basis.
Available DHCP options will be queried by confd on startup and can
then be configured in a flexible manner.
The DHCP option 82 feature has been realized by patching dnsmasq
(see patches/dnsmasq/2.90/0000-relay-agent-info.patch).
Signed-off-by: Stefan Schlosser <sgs@grmmbl.org>
Similar to the run_multiline() method, sometimes files contain more than
one line and a common read_multiline() quickly becomes useful. This is
currently only used by ietf-system for reading /etc/resolv.conf.head.
Also, fix pylint warning for missing encoding to all open() calls.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>