Anonymise the login page: generic "Login" title, lock icon instead
of product logo — makes the device harder to fingerprint.
Add a floating theme toggle button to the login page so users can
switch theme before logging in (cycles auto→light→dark).
Replace the four cluttered sidebar footer buttons (theme, download
config, reboot, logout) with an always-visible topbar user menu.
The dropdown shows the username, three theme options with a checkmark
on the active one, download config, reboot, and logout.
Refactor all handler page-data structs to embed PageData instead of
repeating the four base fields, and add Username (sourced from the
request context) so the topbar can display the logged-in user.
Polish pass on the login card: spacing, focus styles, button weights.
Replace the AES-encrypted-cookie session model with an opaque random
token backed by an in-memory map. The vendored design embedded the
user's username, password, CSRF, and feature flags into the cookie
and persisted the AES key under /var/lib/misc, making the keyfile a
passive credential-recovery oracle — anyone who could read it could
decrypt any captured cookie and recover the plaintext admin password.
Now: cookie is 32 bytes of crypto/rand, base64-url-encoded; sessions
live only in process memory; reboot/respawn/upgrade drops every
active session and the UI's 401 handler bounces the user to /login.
Sliding-window refresh on user activity, janitor goroutine sweeps
expired entries. --session-key flag and /var/lib/misc/webui-session.key
are gone.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Replace flat nav-section-header labels with collapsible <details>/<summary>
accordion groups (Network, Wireless, VPN, Services, System). Groups default
open; user state persists via localStorage. Tablet icon-only mode always
shows all items regardless of open/closed state.
Add badge-up/down/warning/info/neutral utility classes with full dark mode
support, complementing the existing firewall-specific badge variants.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
avahi resolves mDNS hostname conflicts at runtime by appending -2, -3, …
but the advertiser writes its adminurl TXT record with the configured
hostname and never updates it. A device renamed infix-2.local thus keeps
advertising adminurl=http://infix.local, so its card linked to the other
device. Rebase the adminurl onto the actually-resolved host (keeping
scheme, port, and path); a no-op in the common single-device case.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
- Include /run and /tmp in mount-points, likely more interesting than /.
- Include advertised link modes in operational to compare with supported
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
The contact and location leaves were absent from the operational
datastore. Fetch each leaf from the running ds tool and inject
into ietf-system:system.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Two unrelated must expressions referenced schema nodes that don't exist,
emitting warnings on every schema load (and in netopeer2-cli):
- NTP: the iburst/burst deviations put the must on the leaf, so
"ntp:iburst"/"ntp:burst" resolved as a child of the leaf. Use ".".
- WireGuard: deref() of a key *-ref lands on the key's "name" leaf, so
"deref(.)/ks:public-key-format" looked under "name". Use
"deref(.)/../...", and descend into the "public-key" list for the
truststore public-key-bag.
Extend the existing 'show <running|startup|factory>-config' family with an
optional 'path /XPATH' argument that maps straight to the underlying 'copy
-x' flag, and add 'show operational [path /XPATH]' for symmetry with the
configuration datastores.
admin@example:/> show running-config path /ietf-interfaces:interfaces
admin@example:/> show operational path /ietf-system:system-state
Also, improve error feedback from the copy command slightly.
Before:
admin@example:~$ copy running -x /foo
Error: (null) (5)
Error: failed retrieving running-config data
After:
admin@example:~$ copy running -x /foo
Error: Couldn't parse path "/foo": Prefix "foo" not defined. (5)
Error: failed retrieving running-config data
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
cli-pretty prints a friendly message on stdout before any sys.exit(1)
— 'Interface "w" not found', 'Error, top level "ietf-routing:routing"
missing', etc. The wrapper used subprocess.run(..., check=True) and
on non-zero exit caught CalledProcessError, throwing away the captured
stdout and printing the generic exception message instead.
Drop the check=True / try-except dance, always relay stdout, and only
fall back to the generic 'Error running cli-pretty' line when the
subprocess crashed without producing any output.
Before:
admin@bpi:/> show interface w
Error running cli-pretty: Command '['/usr/libexec/statd/cli-pretty',
'show-interfaces', '-n', 'w']' returned non-zero exit status 1.
After:
admin@bpi:/> show interface w
Interface "w" not found
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
The Ethernet packet/RMON counters at the bottom of 'show interface
<name>' were appended with a wider label column than the operational
data above them, breaking visual alignment. Group them under an
"Ethernet Statistics" section heading (Decore.title), same convention
as 'Available Networks' in the wifi scan view.
Narrow the operational-data label column from 20 to 19 chars so the
title bar exactly matches the heading text — a tighter and more
deliberately aligned look. All labels in pr_iface fit within 19
chars except 'lacp system priority' (20); rename it to 'lacp sys
priority' for consistency with the other 'lacp ...' labels (lacp
aggregate id, lacp partner mac, ...) so the new field width works
universally.
Refresh CLI snapshots and doc samples to match.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Update CLI samples across the documentation to the new layered
presentation: physical-medium row when linked (1000baseT/...), bare
MACs, and key: value DATA tokens. Add a short prose block in
ethernet.md and iface.md explaining the layering.
Drop the historical 'show interfaces' (plural) form — removed from
klish years ago — from all user-facing examples and the landing page.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Import ieee802-ethernet-interface@2025-09-10.yang, from IEEE 802.3.2-2025,
and companion ieee802-ethernet-phy-type.yang, replacing the 2019 revision.
Operational interface speed moves to ietf-interfaces:speed, RFC 8343,
eth:speed is now obsolete. Bump infix-interfaces.yang revision to track
the upgrade.
The CLI 'show interface' command renders interfaces as bottom-up layered
protocol rows. Ethernet interfaces a new IEEE link-mode row (1000baseT,
10GbaseLR, ...) is added with 'duplex: full|half' in the DATA column.
Without link the ethernet row is the first row. Tunnels and wifi follow
the same layering: gre/vxlan rows carry remote:/vni: tokens with optional
ethernet sub-row for the L2-bearing variants; wifi rows carry 'station' or
'access-point' ssid:, signal:, stations: tokens.
admin@bpi-76-8f-c2:/> show interface
⚑ INTERFACE PROTOCOL STATE DATA
⇅ lo loopback UP
ipv4 127.0.0.1/8 (static)
ipv6 ::1/128 (static)
⇅ br0 bridge DOWN
│ ethernet 32:2e:3f:76:8f:c2
│ ipv4 192.168.0.1/24 (static)
⇅ ├ lan0 bridge LOWER-DOWN
⇅ ├ lan1 bridge LOWER-DOWN
⇅ ├ lan2 bridge LOWER-DOWN
⇅ └ lan3 bridge LOWER-DOWN
⇅ gre0 gre UP remote: 198.51.100.7
ipv4 10.255.0.1/30 (static)
⇅ sfp1 ethernet DOWN ca:59:f0:77:80:5b
⇅ wan 1000baseT UP duplex: full
ethernet 32:2e:3f:76:8f:c2
ipv4 192.168.0.235/24 (dhcp)
ipv6 fe80::302e:3fff:fe76:8fc2/64 (link-layer)
⇅ wan.10 vlan UP vid: 10
│ ipv4 10.0.10.1/24 (static)
└ wan
⇅ wan.10.20 vlan UP vid: 20
│ ipv4 10.0.10.20/28 (static)
└ wan.10
⇅ wifi0 wifi UP station ssid: corp-net signal: good
ethernet dc:a6:32:00:11:22
ipv4 192.168.7.42/24 (dhcp)
yanger populates phy-type and pmd-type from a static ETHTOOL link-mode
identity table keyed on (port, speed, duplex). Both leaves are populated
for unambiguous media (copper, DAC, copper-T); for generic fiber where
the (port, speed, duplex) tuple can map to multiple PMDs (SR vs LR vs
ER, etc.) only the phy-type family identity is emitted — guessing the
PMD would be misleading. cli_pretty prefers pmd-type (specific) and
falls back to phy-type (family) for display.
yanger also emits ietf-interfaces:speed and fixes a long-standing
'auto-negotation' typo (yanger had never matched ethtool's correctly-
spelled JSON field, so operational auto-negotiation always read
'unknown').
Filling the WG's gap on fixed-speed config
------------------------------------------
IEEE Std 802.3.2-2025 obsoleted the eth:speed leaf without providing a
config-true replacement; the standards-correct way to express what
older Infix configurations called 'fixed speed' is to restrict the set
of PMDs auto-negotiation may advertise. Augment auto-negotiation with
two leaf-lists:
auto-negotiation/advertised-pmd-types config-true, leaf-list of pmd-type
ethernet/supported-pmd-types config-false, leaf-list of pmd-type
Pinning a port to a single mode is now expressed as a single-entry
advertised-pmd-types list. The kernel-supported set is exposed as
operational state for diagnosis — SFP/SFP+ cages report the inserted
module's capabilities, narrowing the list to a single PMD when the
optic only supports one mode (as suggested by @wkz in PR review).
When the supported list collapses to a single entry, yanger uses it
to refine the operational pmd-type leaf — more accurate than the
(port, speed, duplex) lookup for fiber.
confd C apply path (src/confd/src/ieee802-ethernet-interface.c)
translates each advertised pmd-type identity to the corresponding
ETHTOOL_LINK_MODE_*_BIT_*, ORs them into a mask, and emits
'ethtool --change <if> autoneg on advertise 0x<mask>'. An empty
list keeps the historical default of advertising every supported
mode. The (legacy) 'auto-negotiation/enable = false' + speed/duplex
branch is removed — it has no model representation any more.
cli_pretty's detail view gains 'advertised' and 'supported' rows
listing the PMDs in each set. A new _pr_label_list() helper unifies
multi-row rendering across these new rows and the pre-existing
ipv4/ipv6 address rows.
The detailed interface view also gains a 'link mode' row carrying the
pmd-type / phy-type-derived label.
Migration of existing startup configurations
--------------------------------------------
Bump confd version 1.8 → 1.9 to trigger the migration on upgrade.
share/migrate/1.9/10-ethernet-advertise.sh translates old configs of
the form
ethernet { auto-negotiation { enable false; } speed S; duplex D; }
into
ethernet { auto-negotiation { advertised-pmd-types [PMD]; } duplex D; }
mapping (S, D) → PMD via a static lookup covering the copper-T speeds
the deprecated speed leaf historically supported (10/100/1000/2.5G/
5G/10G). Interfaces that don't disable auto-negotiation, or that
lack a speed leaf, are passed through untouched.
Closes#530Closes#805
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
bridge -j vlan global show can return VLAN ranges as
{"vlan": 1, "vlanEnd": 3} instead of individual entries.
The vlans dict was only keyed on the start value, causing
port VLANs 2 and 3 to be reported as "Unexpected".
Also fix typo in error message (brpvlans -> brpvlan).
Move the hostname-triggers-dhcp-client logic from dhcp-client.c into
the centralized dep_hostname() dependency tracker. When the hostname
changes, all interfaces with DHCP client configured are now added to
the diff by the core dependency resolver, so dhcp_client_change() picks
them up through its normal diff-based interface iteration.
When keystore keys change, trigger regeneration of wireguard
interfaces that reference them:
- Asymmetric key change: triggers interfaces using it as private-key
- Symmetric key change: triggers interfaces using it as preshared-key
(both at peers bag-level and individual peer-level)
The 'command' leaf is config, with a strict pattern that doesn't allow
'&', quotes or pipes. Yanger was populating it from podman's full,
untruncated container command -- so any container whose entrypoint
uses shell metacharacters (e.g. sh -c "... && ...") failed YANG
validation.
The symptom: every operational read of /infix-containers:containers
returns SR_ERR_INTERNAL, which in turn fails the whole get-data on
the operational datastore. This breaks case/misc/operational_all and
any RESTCONF/NETCONF read that touches containers.
This was introduced in 59028c4 ("Fix #1466: 'show container' shows no
output"), which added the operational, pattern-less 'cmdline' leaf
but left the old 'command' assignment in place. Drop it -- 'cmdline'
already carries the full command line, and 'command' belongs to
running config.
Note: the failure can look intermittent across test runs because
podman storage is persistent. It only triggers once a container with
a bad-pattern command ends up in 'podman ps -a', including stale or
exited leftovers from earlier runs.
Signed-off-by: Richard Alpe <richard@bit42.se>
Was not correct handled before, a few assumptions was made,
but did not work in reality.
* Fix correct channels for WiFi 6E
* Add missing parameters required for 6ghz to work
The \r-overwrite of an in-progress line breaks when something else
writes to stderr between conout(3) and the final call, leaving blank
"[ OK ]" lines. Cache the description and reprint it whole, so the
final status line is robust to intervening output.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
When an interface has been handed off to a container it lives in
another netns, so `ip neigh/addr flush dev FOO` fails on the host.
The failure aborts dagger, and since interfaces_change() runs before
containers_change() in change_cb(), the container delete path is
never reached -- the stale container keeps the interface trapped in
its netns, breaking the next reconfiguration.
Guard both the neighbor and address flush exit scripts with
`if_nametoindex(ifname)` -- true exactly when the interface is in
the host netns, false for both "in a container" and "already gone".
This replaces the pre-existing `!cni_find(ifname) && if_nametoindex(
ifname)` guard at the addr site: cni_find() added no information
for this check and would popen(container find) for nothing when the
interface had been deleted entirely.
Also harden wrap() in /usr/sbin/container so a stale setup pidfile
doesn't short-circuit Finit's stop attempt -- kill the setup PID and
still ask podman to stop the container.
Fixes#1493
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Add support for static ARP (IPv4) and neighbor cache (IPv6) entries per
interface. Static entries are installed as permanent kernel neighbor
table entries that are never evicted by normal ARP/NDP aging.
Fixes#819
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
On multi-chip DSA hardware (e.g., boards with multiple mv88e6xxx
chips), each switch chip has its own independent PHC device. With
boundary_clock_jbod enabled, ptp4l starts but only disciplines the
active slave port's PHC — the others drift.
Automatically start phc2sys -a alongside any BC or TC instance using
hardware timestamping. It subscribes to ptp4l's UDS socket, tracks
BMCA, and disciplines all non-active PHCs to match the active one.
On single-chip hardware it is a harmless no-op.
CLOCK_REALTIME is intentionally left untouched. Syncing the system
clock to PTP (phc2sys -rr), feeding the PHC from GPS/NTP (ts2phc,
phc2sys reverse), and full multi-source coordination (timemaster) are
planned as follow-on phases; see the issue tracker for the roadmap.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
A container's command line, as reported by podman, may comtain environment
variables, which the current regexp (added in ed4fe58) does not support.
Extend the regexp to allow environment variables and add an operational,
config false, 'cmdline' leaf node to allow any characters to be reported
for the full command line in the operational output.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Unfortunatly the fix was entered in 25.10, but confd was not stepped
up until 25.11, so this should be for 25.10 but now it is for confd
version 1.6 (infix 25.11), as close as we can get.
this is a follwup for commit 7e37fc49a3
confd: prevent IP addresses on bridge ports
Bridge ports should not have IP addresses configured. The IP address
should be configured on the bridge interface itself, not its member ports.
Add YANG must expression to enforce this rule at configuration time.
Fixes#1122
Add a second discovery backend that reads mDNS neighbor data directly
from the sysrepo operational datastore via `copy operational-state -x
/mdns`, selectable with --backend operational.
Add an auto backend (the new default) that tries the operational data
first and falls back to avahi-browse if the `copy` command is
unavailable or mDNS is disabled (visible via "enabled": false in the
JSON). This makes the service work correctly in all configurations
without manual tuning.
Refactor TXT record parsing into parseTxt() and service/host assembly
into buildHosts(), shared by both backends. Extract fetchOpRoot() and
parseOperational() so scanOperational() and scanAuto() share the same
JSON fetch/decode and host-building logic without duplication.
Fix a bug where TXT values containing semicolons were truncated
(parts[9] → strings.Join(parts[9:], ";")), and apply decode() to TXT
values so avahi \DDD escapes are resolved. Add Apple device model
support via the am= (RAOP/AirPlay 1) and model= (AirPlay 2) TXT keys.
Display the last-updated timestamp in 24-hour format regardless of the
browser's locale.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Add reliable avahi client reconnect via explicit free+recreate, reduced
log verbosity (single 10s warning instead of 3×2s loop). Also, binary
TXT record filtering (UTF-8 + XML validity), and finally add a SIGHUP
handler for on-demand reconnect.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
The setting 'stratumweight 0.0' disables stratum in Chrony source
selection (pure distance-based), making client_stratum_selection
non-deterministic on a LAN. Setting it to 1.0 gives srv1 a 1-second
effective advantage per stratum level, which no realistic distance
fluctuation can overcome.
Also correct the YANG descriptions in infix-system and infix-ntp which
had the semantics backwards — claiming 0.0 "ensures lower stratum is
always preferred" when in fact higher values do that.
Fixes#1361
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
After a successful bootstrap confd writes a sentinel to /run/confd.boot
If Finit restarts confd — whether after a crash or a clean exit — the
sentinel is found and the destructive bootstrap phases are skipped:
- gen-config fork (factory/failure configs already exist)
- wipe_sysrepo_shm() (other daemons, e.g. statd, are live)
- sr_install_factory_config() (datastores are already initialised)
- sr_replace_config(NULL, NULL) (running datastore is consistent)
- bootstrap_config() / load startup-config (not needed; sysrepo has
the right state; plugins resync via SR_EV_ENABLED on re-subscribe)
On restart confd reconnects to sysrepo, re-initialises plugins (which
re-subscribe and receive SR_EV_ENABLED to resync with the live running
datastore), then enters the steady-state event loop.
The sentinel lives on tmpfs so a real reboot always produces a clean
slate. Crash-loop protection is delegated to Finit's max-restarts (10).
As a side-effect this also enables a future "run-once" mode for resource
constrained systems: confd can exit after bootstrap and the sentinel
ensures any later restart just re-attaches without re-bootstrapping.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Add a finit_enable/disable/reload() family in core.c that directly
manipulates Finit's service state without fork+exec overhead:
finit_enable(svc) -- create symlink in /etc/finit.d/enabled/
finit_disable(svc) -- remove symlink from /etc/finit.d/enabled/
finit_delete(svc) -- remove both symlink and service entirely
finit_reload(svc) -- utimensat() on .conf to schedule reload
Printf-style variants (finit_enablef/disablef/reloadf) handle
template instance names such as container@foo and hostapd@wlan0.
All systemf("initctl ... enable/disable/touch ...") call sites across
containers, dhcp-server, firewall, hardware, ntp, routing, services,
syslog, and system are converted to the new API.
As a related cleanup in services.c, drop the remaining srx_enabled()
calls in favour of reading the already-fetched config tree directly
via lydx_is_enabled(lydx_get_xpathf(config, ...)), eliminating the
last sysrepo round-trips from that module.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>