Joachim Wiberg ffe5ed1e32 statd, show: fix several operational data reporting bugs
Three bugs found while testing modem support on hardware:

ietf_system.py: "interface": null written to DNS server entries when
  no interface is associated, causing LY_EVALID in the ietf-system
  schema validator.  Only include the key when the interface name is
  non-empty.

ietf_system.py: empty list inserts (user [], server [], options [],
  search []) overwrote configured data in the operational store instead
  of leaving it intact.  Guard each insert so operational data only
  shadows configured data when there is something to report.

show system: CPU temperature reported only the first sensor named
  exactly "cpu", "soc", or "core".  Platforms with multiple thermal
  zones (e.g. BPI-R4 exposes cpu and cpu1) always showed only one
  reading.  Collect all sensors whose name matches a CPU/SoC prefix
  and report the maximum.

statd.c: yanger parse errors logged without model name or libyang
  error string, making failures hard to diagnose.  Include both.

Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
2026-06-07 20:50:29 +02:00
Joachim Wiberg b6a7d0f294 cli: new admin-exec level command 'show nacm'
Show operational details about nacm and user//group mappings.

Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
2026-01-23 06:12:21 +01:00
Mattias Walström b75d6af84e test: Update statd test data 2026-01-02 22:32:59 +01:00
Richard Alpe 72ffbf6254 test: update unit data with service statistics
Signed-off-by: Richard Alpe <richard@bit42.se>
2025-12-17 15:34:13 +01:00
Richard Alpe c119436f97 confd: augment new services container to ietf-system
This patch adds operational data support for system services. The
data is in a generic format but is intended to be able to represent
finit information (initctl) nicely.

The reason for augmenting this to ietf-system and not to
infix-services is that we consider this generic system information
which is totally disconnected from what ever services infix might
provide.

In this first state we only support pid, name, description and state.
Making the data look something like:

  "infix-system:services": {
    "service": [
      {
        "pid": 1185,
        "name": "udevd",
        "status": "running",
        "description": "Device event daemon (udev)"
      }]

Signed-off-by: Richard Alpe <richard@bit42.se>
2025-10-27 15:30:29 +01:00
Mattias Walström 12e5b4c1b4 test: Update files for unittest 2025-04-30 11:51:45 +02:00
Mattias Walström 44be4e57f0 test: statd: Update unit testfiles 2025-04-23 13:45:49 +02:00
Joachim Wiberg cb73ddf6bf test: update unit test with DNS resolver operational data
With support for dns resolver in place, the ietf-system output needs to
be complemented with additional data collected from both the dnsmasq and
openresolv subsystems.

System date taken from 'client3' in the Infix DHCP server-subnets test.

Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
2025-01-31 13:56:40 +01:00
Tobias Waldekranz f4c9a57bb5 test: statd: Add unittest for ietf-{hardware,system} 2025-01-20 13:44:14 +01:00